PRODUCT DISPLAY

WPT Hybrid Solar Inverter 4KW-7KW 48V/96V/192V

■ Hybrid Solar Inverter Feature



1. Hybrid solar inverter with built-in PWM or MPPT solar controller optional;
2. Adopt EI transformer, strong impact resistance ability;
3. Pure sine wave output adapt a variety type of loads ;
4. Intelligent LCD integrated display, real-time view of operating status and setting data;
5. AC charging current 0~20A adjustable, more flexible user battery capacity configuration;
6. 3 type working modes (AC first / Battery first / Saving energy mode);
7. Adding fault code interrogate function, easy for real-time operating status monitoring;
8. Supports diesel or gasoline generator, adapt any tough electricity occasions;
9. Protection against overload, overheat, short circuits, safety and reliable;
0. Support RS485 communication port / mobile APP (optional).



■ Hybrid Solar Inverter Specification



Specification
Model WP-T 40248/96 50248/96 60248/96 70248/96/192
Rated Power 4KW 5KW 6KW 7KW
Peak Power(20ms) 12KVA 15KVA 18KVA 21KVA
Start Motor 3HP 4HP 4HP 5HP
Battery Voltage 48/96VDC 48/96VDC 48/96VDC 48/96/192VDC
Size(L*W*Hmm) 490*260*500
Packing Size(L*W*Hmm) 550*320*560
N.W.(kg) 45 48 50 54
G.W.(kg) 49 52 54 58
Installation Method Tower
Parameter
Input DC Input Voltage Range 10.5-15VDC(Single battery voltage)
AC Input Voltage Range
73VAC~138VAC(110VAC) /  83VAC~148VAC(120VAC) / 145VAC~275VAC(220VAC) / 
155VAC~285VAC(230VAC) /  165VAC~295VAC( 240VAC)
AC Input Frequency Range 45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
Max AC charging current 0A~20A(Depending on the model,The maximum charging power is 1/4 of the rated power)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Output Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 110VAC±2%  / 120VAC±2%  / 220VAC±2%  / 230VAC±2%  / 240VAC±2% 
Output Frequency(Battery Mode) 50Hz±0.5 or 60Hz±0.5
Output Wave(Battery Mode) Pure Sine Wave
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Follow input
Output Frequency(AC Mode) Tracking Automatically
Output waveform
distortion(Battery Mode)
≤3%(Linear load)
No load loss(Battery Mode) ≤2.5% rated power
No load loss(AC Mode)  ≤2% rated power( charger does not work in AC mode)
No load loss
(Energy saving Mode)
≤10W
Battery Type VRLA Battery Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage)
Customize battery
Charging and discharging parameters of different types of batteries can be customized according to user requirements
 (charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm Factory default: 11V(Single battery voltage)
Battery undervoltage protection  Factory default: 10.5V(Single battery voltage)
Battery overvoltage alarm Factory default: 15V(Single battery voltage)
Battery overvoltage protection Factory default: 17V(Single battery voltage)
Battery overvoltage recovery voltage Factory default: 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller
(Optional)
Charging Mode PWM or MPPT
charging current 48V(PWM:10A~120A/MPPT:10A~100A) / 96V(50A/100A(PWM or MPPT))      
PV Input Voltage Range PWM:  60V-88V(48V system); 120V-176V(96V system) / MPPT: 60V-120V(48V system); 120V-240V(96V system)
Max PV Input Voltage(Voc)
(At the lowest temperature)
PWM:  100V(48V system); 200V(96V system) / MPPT: 150V(48V system); 300V(96V system)
PV Array Maximum Power
48V system: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)/
                     4480W(80A)/5600W(100A)/6720W(PWM 120A)/5.6KW&11.2KW(MPPT 100A/200A);
96V system:  5.6KW(50A)/11.2KW(100A);
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Cooling fan in intelligent control
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise ≤55dB
Elevation 2000m(More than derating)
Humidity 0%~95% ,No condensation
Note: All specifications are subject to charge without prior notice