■ Solar DC to AC Converter Feature



1  Solar converter dc to ac built-in PWM or MPPT controller optional;

2  Pure sine wave output;

3  High efficiency toroidal transformer lower loss ;

4  Intelligent LCD integration display;

5  AC charge current 0-20A adjustable; battery capacity configuration more flexible;

6  Three types working modes adjustable:AC first, DC first, energy-saving mode;

7  Frequency adaptive function, adapt to different grid environments;

8  Added fault code query function,facilitate user to monitor the operation state in real time;

9  Supports diesel or gasoline generator, adapt any tough electricity situation;

10  RS485 communication port/APP optional.



■ Solar DC to AC Converter Specification



Specification
Model WD-T 303240
(303)
403384
(403)
Rated Power 30KW 40KW
Peak Power(20ms) 90KVA 120KVA
Start Motor 15HP 20HP
Battery Voltage 240VDC 384VDC
Size(L*W*Hmm) 721x400x1002
Packing Size(L*W*Hmm) 775x465x1120
N.W.(kg) 167 192
G.W.(kg) 190 215
Installation Method Tower
Input DC Input Voltage Range 10.5-15VDC(Single battery voltage)
AC Input Voltage Range 92VAC~128VAC(110VAC) / 102VAC~138VAC(120VAC) /  185VAC~255VAC(220VAC) / 
195VAC~265VAC(230VAC) /  205VAC~275VAC( 240VAC) (8KW~40KW)
AC Input Frequency Range 45Hz~55Hz(50Hz)/ 55Hz~65Hz(60Hz)
Max AC charging current 0A~20A(Depending on the model,The maximum charging power is 1/4 of the rated power)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Output Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 110VAC±2%  / 120VAC±2%  / 220VAC±2%  / 230VAC±2%  / 240VAC±2% 
Output Frequency(Battery Mode) 50Hz±0.5 or 60Hz±0.5
Output Wave(Battery Mode) Pure Sine Wave
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Follow input
Output Frequency(AC Mode) Tracking Automatically
Output waveform distortion
(Battery Mode)
≤3%(Linear load)
No load loss(Battery Mode) ≤1% rated power
No load loss(AC Mode)  ≤2% rated power( charger does not work in AC mode)
No load loss
(Energy saving Mode)
≤10W
Battery Type
(selectable)
VRLA Battery Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
 (charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm Factory default: 11V(Single battery voltage)
Battery undervoltage protection Factory default: 10.5V(Single battery voltage)
Battery overvoltage alarm Factory default: 15V(Single battery voltage)
Battery overvoltage protection Factory default: 17V(Single battery voltage)
Battery overvoltage recovery voltage Factory default: 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Converter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller
(Optional)
Charging Mode PWM or MPPT
charging current 50A/100A
PV Input Voltage Range PWM: 300V-400V(240V system); 480V-704V(384V system) / MPPT:  300V-400V(240V system);480V-640V(384V system)
Max PV Input Voltage(Voc)
(At the lowest temperature)
PWM: 500V(240V system) ;750V(384V system) / MPPT: 500V(240V system) ;800V(384V system)
PV Array Maximum Power 240V system: (PWM:14KW(50A)/28KW(100A)) / (MPPT:14KW(50A)/14*2KW(100A));
384V system: (PWM:22.4KW(50A)/44.8KW(100A)) / (MPPT:22.4KW(50A)/22.4*2KW(100A))
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Cooling fan in intelligent control
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise ≤55dB
Elevation 2000m(More than derating)
Humidity 0%~95% ,No condensation