PRODUCT DISPLAY

HP DC to AC Power Inverter 3000W/5000W 24V/48V Factory

■ DC to AC Inverter Feature



1 High frequency design, high power density, small size, high efficiency, low no-load loss.

2 DC to AC power inverter pure sine wave output, any types of loads adaptable. 
3 Battery charge and discharge voltage parameters adjustable,suitable for different types of batteries,can prolong the life of the battery and improve system performance.
4 AC charge current 0~60A adjustable,battery capacity configuration more flexible.
5 Three working modes adjustable:AC first,Battery first,PV first.
6 Output voltage/frequency adjustable function,adapt to different grid environment.
7 Extra wide voltage and frequency input range, support mains or generator.
8 LED+LCD display, easy operation and data checking,can set each function and data directly.
9 Multi-protection function(overload,over temperature,short circuit protection and so on).
10 RS485 communication port/APP optional.



■ DC to AC Inverter Specification



Specification
Model: HP 32224 50248
Rated Power 3200W 5000W
Peak Power(20ms) 9600VA 15KVA
Battery Voltage 24VDC 48VDC
Product Size(L*W*Hmm) 476x350x118
Package Size(L*W*Hmm) 502x402x165
N.W(Kg) 11.5 11.8
G.W(Kg) 12.5 12.8
Installation Method Wall-Mounted
Input DC Input Voltage Range 21VDC-30VDC 42VDC-60VDC
Rated AC input voltage 220VAC  / 230VAC  / 240VAC
AC Input Voltage Range 170VAC~280VAC (UPS mode)/ 120VAC~280VAC(INV mode)
AC Input Frequency Range 45Hz~55Hz(50Hz),55Hz~65Hz(60Hz)
Output Output efficiency(Battery/PV Mode) 94%(Peak value)
Output Voltage(Battery/PV Mode) 220VAC±2%  / 230VAC±2%  / 240VAC±2%
Output Frequency(Battery/PV Mode) 50Hz±0.5 or 60Hz±0.5
Output Wave(Battery/PV Mode) Pure Sine Wave
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Follow input
Output Frequency(AC Mode) Follow input
Output waveform distortion
Battery/PV Mode)
≤3%(Linear load)
No load loss(Battery Mode) ≤1% rated power
No load loss(AC Mode) ≤1% rated power(charger does not work in AC mode)
Battery  Battery
 Type
VRLA Battery Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Maximum charging current (Mains or PV or mains + PV)(Built-in MPPT controller model) 60A 50A
Maximum charging current
(Built-in PWM controller model)
Mains60A+
PWM controller charging current
Mains50A+
PWM controller charging current
Charging method Three-stage (constant current, constant voltage, floating charge)
Protection Battery low voltage alarm Battery undervoltage protection value+0.5V(Single battery voltage)
Battery low voltage protection Factory default: 10.5V(Single battery voltage)
Battery over voltage alarm Constant charge voltage+0.8V(Single battery voltage)
Battery over voltage protection Factory default: 17V(Single battery voltage)
Battery over voltage recovery voltage Battery overvoltage protection value-1V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Working Mode Mains priority/Solar priority/Battery priority(Can be set)
Transfer Time ≤4ms
Display LCD+LED
Thermal method Cooling fan in intelligent control
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise ≤55dB 
Elevation 2000m(More than derating)
Humidity 0%~95% (No condensation)

Note: All specifications are subject to charge without prior notice.